Item Name | Switch Thermostatic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
NIIN | 00-599-9188 (005999188) |
NCB Code | USA (00) |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
153C5841P1 | other | switch thermostatic | Avl | RFQ |
M175 | essex group inc controls div lex | switch thermostatic | Avl | RFQ |
M175 | essex group inc suflex iwp div | switch thermostatic | Avl | RFQ |
436-747-72 | essex group inc controls div lex | switch thermostatic | Avl | RFQ |
436-747-72 | essex group inc suflex iwp div | switch thermostatic | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.312 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.770 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.455 INCHES MINIMUM AND 0.465 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTYX | CONTACT STIMULUS RATING | 77.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 72.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
ABKW | OVERALL HEIGHT | 0.344 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.812 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.123 INCHES MINIMUM AND 0.133 INCHES MAXIMUM |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR |
5962-01-029-7548 (5962010297548) | 5905-00-628-4578 (5905006284578) | 5935-00-052-8552 (5935000528552) | 5905-01-648-3827 (5905016483827) |
5905-01-520-3328 (5905015203328) | 5925-01-224-4518 (5925012244518) | 5935-01-052-5884 (5935010525884) | 5995-01-373-6057 (5995013736057) |
5905-01-221-8634 (5905012218634) | 5998-01-164-2209 (5998011642209) | 5935-01-159-2488 (5935011592488) | 5935-01-249-8276 (5935012498276) |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |